Elementary Energy Usage
Bowman Woods
Bowman Woods is a PK-5 50,906 square foot elementary school housing approximately 475 students and 58 staff. The building is primarily heated and cooled using high efficiency forced air conventional systems.
Energy Usage
Natural Gas (Therms): FY2009 – 15,873; FY2010 – 14,958; FY2011 – 16,547; FY2012 – 15,144; FY2013 – 15,279: FY2014 – 16,758, FY2015 – 12,991; FY2016 – 10,877; FY2017 – 10,635
Electricity (kWh): FY2009 – 461,700: FY2010 – 399,500; FY2011 – 471,900; FY2012 – 428,700; FY2013 – 496,400: FY2014 – 430,200, FY2015 – 450,300; FY2016 – 390,600; FY2017 – 393,300
Equipment
- High Efficiency Air Conditioning
- Heat Recovery Air Exchange Units
- High Efficiency Furnaces
- Energy Efficient Door Replacement
Echo Hill
Echo Hill is a PK-5, 78,000 square foot elementary school housing approximately 549 students and 71 staff. The building is primarily heated and cooled using high efficiency geothermal ground source heat pump systems. School water heating is electricity.
Energy Usage
Natural Gas (Therms): FY2009 – 438 (11 months); FY2010 – 297; FY2011 – 264; FY2012 – 304; FY2013 – 281; FY2014 – 379; FY2015 – 394; FY2016 – 306; FY2017 – 342
Electricity (kWh): FY2009 – 880,600 (11 months); FY2010 – 965,200; FY2011 – 1,039,800; FY2012 – 1,106,000; FY2013 – 929,000; FY2014 – 896,400; FY2015 – 957,600; FY2016 – 837,400; FY2017 – 826,200
Equipment
- Occupancy Sensors – WattStopper
- Variable Speed Drives on Geothermal Pumps
- Daylight Sensoring in Hallway
- Installed water mixing valves
- Vend Misers on Vending Machines
Indian Creek
Indian Creek is a K-5, 42,200 square foot elementary school housing approximately 505 students and 60 staff. The building is primarily heated and cooled using high-efficiency geothermal ground source heat pump systems converted from natural gas in 2010. School water heating is natural gas. It is part of the main Linn-Mar campus electric system.
Energy Usage
Natural Gas (Therms): FY2009 – 10,874; FY2010 – 3594; FY2011 – 3527; FY2012 – 1696; FY2013 – 1406; FY2014 – 1867; FY2015 – 4,101; FY2016 – 2,596; FY2017 – 4,439;
Electricity (kWh): Electricity usage is part of the campus electricity usage.
Programs
- Energy Audit – Alliant through Michaels Engineering
Equipment
- Converted to ground source heat pumps for cooling and heating.
- Replaced windows with energy efficient windows.
- LED parking lot lighting
- Roof replacement
- Exit sign replacement
Linn Grove
Linn Grove is a PK-5, 78,000 square foot elementary school housing approximately 485 students and 74 staff. The building is primarily heated and cooled using high-efficiency geothermal ground source heat pump systems. School water heating is natural gas.
Energy Usage
Natural Gas (Therms): FY2009 – 3766; FY2010 – 3630; FY2011 – 4289; FY2012 – 4369; FY2013 – 2499; FY2014 – 2403; FY2015 – 2591; FY2016 – 3,069; FY2017 – 2,421
Electricity (kWh): FY2009 – 1,029,200; FY2010 – 940,000; FY2011 – 948,600; FY2012 – 1,106,400; FY2013 – 934,000; FY2014 – 1,088,000; FY2015 – 1,249,200; FY2016 – 921,200; FY2017 – 916,000
Programs
- Energy Audit – Alliant through Michaels Engineering
Equipment
- Occupancy Sensors – Lutron Radio Controlled
- Daylighting Sensors in Main Hallways
- Installed water mixing valves
Novak
Novak is a PK-5, 78,000 square foot elementary school housing approximately 460 students and 71 staff. The building is primarily heated and cooled using high-efficiency geothermal ground source heat pump systems. School water heating is electricity.
Energy Usage
Natural Gas (Therms): FY2011 – 2616; FY2012 – 2580; FY2013 – 2627; FY2014 – 2844; FY2015 – 2,775; FY2016 – 2,145; FY2017 – 2,908
Electricity (kWh): FY2011 – 793,200; FY2012 – 867,600; FY2013 – 799,200; FY2014 – 879,600; FY2015 – 974,400; FY2016 – 887,200; FY2017 – 814,400
Programs
- Energy Audit – Alliant through Michaels Engineering
Westfield
Westfield is a K-5 61,588 square foot elementary school housing approximately 424 students and 56 staff. The building is primarily heated and cooled using a four pipe boiler system with condensing unit.
Energy Usage
Natural Gas (Therms): FY2009 – 38,092: FY2010 – 30,374; FY2011 – 20,915; FY2012 – 34,597; FY2013 – 35,586; FY2014 – 45,390; FY2015 – 42,892; FY2016 – 38,242; FY2017 – 36,036
Electricity (kWh): FY2009 – 634,682: FY2010 – 610,176; FY2011 – 521,472; FY2012 – 674,488; FY2013 – 636,288; FY2014 – 713,088′ FY2015 – 691,776; FY2016 – 691,968; FY2017 – 755,039
Equipment
- Replace Metal Halide Gym Lighting with Fluorescent
Wilkins
Wilkins is a K-5 48,800 square foot elementary school. The building is primarily heated and cooled using high efficiency geothermal ground source heat pump systems converted from natural gas in 2010.
Energy Usage
Natural Gas (Therms): FY2009 – 38,092: FY2010 – 30,374; FY2011 – 20,915; FY2012 – 34,597; FY2013 – 35,586; FY2014 – 45,390; FY2015 – 42,892; FY2016 – 38,242; FY2017 – 36,036
Electricity (kWh): FY2009 – 634,682: FY2010 – 610,176; FY2011 – 521,472; FY2012 – 674,488; FY2013 – 636,288; FY2014 – 713,088′ FY2015 – 691,776; FY2016 – 691,968; FY2017 – 755,039